{"id":45885,"date":"2026-11-25T09:07:23","date_gmt":"2026-11-25T08:07:23","guid":{"rendered":"https:\/\/www.odyssee-environnement.fr\/?p=45885"},"modified":"2026-11-25T09:07:26","modified_gmt":"2026-11-25T08:07:26","slug":"all-about-steam-boilers-in-intermittent-operation","status":"publish","type":"post","link":"https:\/\/www.odyssee-environnement.fr\/en\/all-about-steam-boilers-in-intermittent-operation\/","title":{"rendered":"All about steam boilers in intermittent operation"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Protect during dowtime. Be ready for production<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Industrial equipment generally performs best under stable operating conditions. Repeated starts and stops introduce additional challenges, and steam boilers are a good example.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A microbrewery may run its boiler only once or twice a week, leaving it idle between production days. At the other end of the scale, thermal power plants may cycle on and off as electricity demand and weather conditions change.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Whether it is a small low-pressure boiler or a large high-pressure unit, these recurring shutdowns raise the same concerns: corrosion during downtime and potentially difficult restarts. Water treatment must therefore support the entire operating cycle, from steam production through shutdown to the next startup.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conventional Treatments: The Challenge of Repeated Shutdowns<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Conventional boiler treatment typically combines appropriate pH control, deposit control and oxygen management. Where oxygen scavengers are used, they complement thermal deaeration by reacting with residual dissolved oxygen. Their effectiveness depends on the chemical selected, temperature, pH and sufficient reaction time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">During shutdown, conditions change. As the boiler cools, air may enter the system, introducing fresh oxygen. With little or no water circulation, scavengers may not be distributed evenly, and the chemical reserve can become depleted locally, even when a bulk water sample still shows an acceptable residual.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An oxygen scavenger residual alone therefore does not guarantee protection at every metal surface during downtime. Repeated shutdowns require a suitable preservation procedure, with treatment distributed before shutdown, oxygen ingress controlled and water chemistry monitored.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For boilers operating only once or twice a week\/month, this creates a recurring operational requirement: maintaining protection between production runs while keeping the system ready for its next startup.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Technical and Economic Alternative: Film-Forming Amines<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Rather than relying on removing oxygen from the water, film-forming amines act directly at the metal surface. They adsorb onto it, creating a thin hydrophobic barrier that helps protect against corrosion.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For intermittently operated boilers, the key advantage is protection that can persist during downtime. Once properly established, the film helps protect treated surfaces between operating periods, without the need of an oxygen scavenger.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The economic value extends beyond chemical consumption: limiting shutdown corrosion can help reduce maintenance, preserve equipment and support more reliable restarts. For a microbrewery, this means keeping the boiler ready for the next production day. For a cycling power plant, it means supporting availability when demand returns.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Performance depends on selecting the right formulation, establishing the film before shutdown and monitoring the system. Film-forming amines must therefore be integrated into a treatment and preservation strategy suited to the boiler\u2019s pressure, materials and operating cycle.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Case Study &#8211; A microbrewery Boiler<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">System in place<br>\u2022Steam Boiler : COLUMBIA 20 HP<br>\u2022Manufacturing year : 2015<br>\u2022Combustible : Gas<br>\u2022Inlet : Softened water<br>\u2022Condensates returns : &gt; 95%<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"451\" src=\"https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-4-1024x451.jpeg\" alt=\"\" class=\"wp-image-45886\" title=\"\" srcset=\"https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-4-1024x451.jpeg 1024w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-4-300x132.jpeg 300w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-4-767x338.jpeg 767w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-4-1536x677.jpeg 1536w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-4.jpeg 1889w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"451\" src=\"https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-2-2-1024x451.jpeg\" alt=\"\" class=\"wp-image-45887\" title=\"\" srcset=\"https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-2-2-1024x451.jpeg 1024w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-2-2-300x132.jpeg 300w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-2-2-767x338.jpeg 767w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-2-2-1536x677.jpeg 1536w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-2-2.jpeg 1889w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption><\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>This microbrewery operates its steam boiler only once or twice a week, leaving it idle between brewing days. These repeated shutdowns make corrosion protection during downtime a central concern.<\/strong><br>As a small installation, it also receives limited technical supervision. With the brewery team focused on production, water testing, chemical dosing checks and shutdown procedures can be difficult to maintain consistently.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The system showed severe corrosion despite efforts to maintain the recommended sulfite residual.<\/strong> This highlighted the difficulty of translating an acceptable bulk water residual into effective protection throughout repeated shutdowns.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The challenge was therefore twofold: protecting the boiler through repeated start-stop cycles while keeping treatment practical for the brewery team.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-5-1024x683.jpeg\" alt=\"\" class=\"wp-image-45888\" title=\"\" srcset=\"https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-5-1024x683.jpeg 1024w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-5-300x200.jpeg 300w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-5-768x512.jpeg 768w, https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/Nouvelle-note-5.jpeg 1536w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The treatment was switched to a <strong>food-grade, NSF G6-registered formulation combining film-forming and alkalizing amines<\/strong>. Dosing was adjusted to target 750 ppm as product in the boiler water, regarding make-up<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.odyssee-environnement.fr\/wp-content\/files\/2026\/11\/odyssee-environnement-articles-En_ST_ODYVAP_VA_30_Product_Bulletin_24.08-29.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Product Bulletin of the Food-Grade NSF G6 Certified Product<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">No service visits took place during the following two months, and no other changes or adjustments were made.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Iron concentration decreased from 5 ppm before the change to 0.2 ppm after three months, a 96% reduction<\/strong>, accompanied by a visible improvement in water appearance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Case of power generation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Power plants face growing pressure to control costs while adapting to changing electricity demand and an increasing share of renewable generation. For conventional thermal units, this can mean more frequent starts and stops, operation at lower loads and extended shutdowns whose duration is not always known in advance.<br>These conditions make corrosion control across the steam\/water cycle particularly challenging. Film-forming products offer an approach designed to protect metal surfaces during both operation and shutdown, establishing a hydrophobic barrier that repels water.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Their application has been widely investigated through industry research and field experience, leading to dedicated technical guidance:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>IAPWS (2019)<\/strong> \u2014 Application of Film Forming Substances in Fossil, Combined Cycle, and Biomass Power Plants. Originally published in 2016; revised in 2019.<\/li>\n\n\n\n<li><strong>IAPWS (2019)<\/strong> \u2014 Application of Film Forming Substances in Industrial Steam Generators.<\/li>\n\n\n\n<li><strong>EPRI (2020)<\/strong> \u2014 Interim Guidelines for Film-Forming Product Application at Conventional and Combined-Cycle Fossil Power Plants. Report No. 3002013952.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Protect during dowtime. Be ready for production Industrial equipment generally performs best under stable operating conditions. Repeated starts and stops introduce additional challenges, and steam boilers are a good example. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":45891,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-45885","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-non-classifiee"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/posts\/45885","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/comments?post=45885"}],"version-history":[{"count":1,"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/posts\/45885\/revisions"}],"predecessor-version":[{"id":45890,"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/posts\/45885\/revisions\/45890"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/media\/45891"}],"wp:attachment":[{"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/media?parent=45885"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/categories?post=45885"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.odyssee-environnement.fr\/en\/wp-json\/wp\/v2\/tags?post=45885"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}